PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
2022
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studi…
Building Partial Discharge Signal Wireless Probes
2014
This chapter focuses on the evaluation of the performances of different antenna sensors suitable for Partial Discharge (PD) measurements. Monopole, triangular and spherical antennas were simulated by means of the surface method of moments. The transmitting system is modeled by a power electronic device with a fault current between two metal plates. The shape of the simulated, transmitted and received signals, has been compared to verify the sensor that provides the best fidelity among the three. The auto-correlation function and the Pearson correlation index are adopted here for the comparison. A discussion on the dynamic characteristic of the different antenna probes and their use in diffe…
Electrical Aging Tests on Enameled Wire Exposed to Gamma Irradiation
2011
Characteristics of partial discharges in an experimental setup reproducing HVDC cable insulation operating conditions
2021
The occurrence of Partial Discharge (PD) inside a cavity subjected to HVDC voltage can be considered as one of the most likely sources of insulation ageing and failure. In practical applications, the recognition of PD under HVDC is more difficult than under AC stress because of the lower repetition rates and the impossibility to obtain a PD pattern synchronized with the waveform of the applied voltage. In this paper, the relationship between conduction phenomena in dielectrics and the occurrence of PD is investigated by means of a novel experimental setup. A couple of dielectric cells connected in series is subjected to various HVDC stress levels. The applied voltage is divided between the …
A portable instrument for the location and identification of defects generating PD
2011
A portable instrument based on an antenna probe and suitable for partial discharge detection, have been characterized through both laboratory and on-site experiments carried out on coils and stator windings of ac rotating machines. The antenna probe allows the capture of electromagnetic waves in a bandwidth of 0.1–100 MHz. Pulse signals and ac supply voltage reference are obtained by means of high-pass and low-pass filters, respectively, so avoiding the need of a direct connection with the objects under test. By this way, real-time phase resolved partial discharge patterns can be derived. Results of a comparison of the diagnostic information provided by PD patterns due to conducted and irra…
Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case
2017
This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…
Space Charges and Partial Discharges Simultaneous Measurements under DC Stress
2016
In the field of HVDC, the main causes of insulation aging are due to the space charge and PD phenomena. In particular, the purpose of the present work is to verify a possibility to measure simultaneously the space charge and the PDs under DC stress in order to evaluate the correlation between both phenomena. The space charge was measured by using a modified PEA cell and PDs were measured by using a novel wireless sensor system. The space charge profile and the PD pulses carried out simultaneously have been reported and discussed.
A digital device for the diagnosis of insulation systems
2004
A complete innovative measurement system (D2SI - device for the diagnosis of insulation systems) for both acquisition, analysis and processing of partial discharge signals generated in insulation systems under voltage stress (IEC standard), was designed and realized; several measurements on practical insulation systems demonstrated the full and correct equipment operation.